Mitsubishi Heavy Industries Air Conditioner Error Codes

Error Codes and Troubleshooting for Mitsubishi Heavy Industries Air Conditioners

Error codes are displayed on your remote control and are a great way to see what issues your aircon might be having. Below is a list of Mitsubishi Heavy Industries air conditioner error codes. If you see your error in the list and are not certain you can fix the problem then it is suggested you contact your local air conditioning contractor. You can relay the error code and if the contractor cannot help you fix the problem over the phone you will need to arrange a service inspection.

Mitsubishi Heavy Industries air conditioner error codes

Mitsubishi Heavy Industries Air Conditioner Error Codes

E1Remote control communication error
E2Duplicate indoor unit address
E3Outdoor unit signal line error
E5Communication error during operation
E6Internal heat exchanger temperature thermistor abnormality (Thi-R)
E7Internal return air temperature thermistor abnormality (Thi-A)
E9Unloading problem
E10Excessive number of indoor units with remote control
E12Address setting error with mixed setting method
E16Internal fan motor abnormality (FDT series)
E16Internal fan motor abnormality (FDK series)
E19Indoor unit operation control unload motor control mode abnormality
E28Remote control temperature thermistor abnormality (ThC)
E30Incompatible connection of indoor and outdoor unit
E31Replicated outdoor unit address no.
E32Open L3 phase in the primary side power supply
E36Drain pipe temperature error (Tho-D1, D2)
E36Liquid overflow abnormality
E37Abnormalities of external heat exchanger temperature thermistor (Tho-R) and sub-cooling coil temperature thermistor (Tho-SC, -H)
E38Outdoor temperature thermistor abnormality (Tho-A)
E39Drain pipe temperature thermistor abnormality (Tho-D1, D2)
E40High pressure abnormality (63H1-1, 2 active)
E41 (E51)Power transistor overheating
E42Power failure (CM1, 2)
E43Over-connected indoor units, over-total capacity connection
E45Communication error between inverter PCB and external control PCB
E46Mixed address setting methods available on the same network
E48External DC fan motor abnormality
E49Low pressure abnormality
E53/E55Suction pipe temperature thermistor abnormality (Tho-S), Under-dome temperature thermistor abnormality (Tho-C1, C2)
E54High pressure sensor (TSH) Low pressure sensor (PSL) abnormality
E56Power transistor temperature thermistor abnormality (Tho-P1, Tho-P2)
E58Abnormal compressor with loss of synchronization
E59Compressor start failure (CM1, 2)
E60Rotor position detection failure (CM1, 2)
E61Communication error between main unit and backup units System error
E63Emergency stop

Common Mitsubishi Heavy Industries Air Conditioner Problems

Water is leaking from my air conditioner.

If your indoor unit is leaking water, there might be several problems. Your air conditioner can have a blocked drain line, be improperly fitted, preventing water from dripping out of the unit, or have a refrigeration problem. Please get in touch with your local air conditioning contractor if this happens.

My air conditioner will not start.

There are several things you may do to figure out if your air conditioner isn’t working properly. First, make sure the remote batteries are completely charged. If necessary, replace them with new ones. In the event that you own a wall controller, see if the remote is displaying any error codes. Our Split systems display trouble codes by a series of flashes on the Run light and Timer light.whether it is safe to do so, make sure the electricity has not been cut off, see whether the circuit breaker has tripped, and try to reset the circuit breaker. Please get in touch with your local air conditioning contractor if your air conditioner still won’t switch on.

My air conditioner has water running from the outdoor unit drain pipe.

This is encouraging. When the outdoor unit is turned on and water is flowing out of the drain pipe adjacent to it, the air conditioning unit is functioning appropriately and was placed correctly.

Can i run my air conditioner all night?

Yes. You may operate a Mitsubishi Heavy Industries air conditioner safely through the whole night while you’re asleep. Additionally, you may use the night mode option to guarantee the device operates effectively at night.

Should i leave my windows open when operating the air conditioner?

We advise closing all of your windows to maximiee the performance of your air conditioner and to heat or cool your home more quickly.

Other Air Conditioner Brand Error Codes

Enquire now!

Simply fill out your details below & our team will be in touch!

OR
Fast Breakdown and Repair Services:

Call Now for Expert Electrical and Air Conditioning Support

Choose the service of Split System Air Conditioning that you need
Replacing an AC
Installing new AC