LG Air Conditioner Error Codes

Error Codes and Troubleshooting for LG Air Conditioners

This page contains a list of all the LG air conditioner malfunction error codes and their potential causes. You can determine the state and problem with the air conditioner or air conditioning system by looking up the error code. LG indoor and outdoor air conditioner fault codes.

LG air conditioner error codes

LG Air Conditioner Indoor Unit Error Codes

Error CodeProbable Cause
1Indoor unit room temperature sensor error
2Indoor unit inlet pipe sensor error
4Float switch error (optional)
5Communication error between indoor unit and outdoor units
6Indoor unit outlet pipe sensor error
9Indoor unit EPROM error
10Indoor unit BLDC motor fan lock
12Indoor unit middle pipe sensor error

LG Air Conditioner Outdoor Unit Error Codes

Error Code Probable Cause
21 DC Peak (IPM Fault); Compressor DC voltage was too high
22 Current Transformed (CT2) error; Alternating current (AC) input too high
23 DC Link Low Volt
25 AC Low/High Volt
26 DC Comp Position Error (not providing rotation), Locking
27 PSC Fault; Current to inverter compressor between AC and DC converter circuit too high
28 Inverter compressor DC voltage is too high
29 Inverter compressor amperage is too high
31 Current-to-current transformer (CT) thermistor is too low
32 Inverter Compressor Discharge Pipe (D-Pipe) Overheat
40 CT Sensor Error; Thermistor is disconnected or shorted out
41 D-Pipe Sensor INV is disconnected or shorted out
44 Outdoor Air Sensor is disconnected or shorted out
45 Middle thermistor of outdoor unit condenser coil is disconnected or shorted out
46 Outdoor unit suction line thermistor is disconnected or shorted out
48 Outdoor unit coil outlet (liquid line) thermistor is disconnected or shorted out
53 Communication failure from outdoor unit to indoor unit
60 Outdoor unit printed circuit board (PCB) EPROM check sum error
61 Outdoor unit condenser coil temperature is too high
62 Outdoor unit inverter compressor PCB heat sink temperature is too high
63 Condenser coil pipe thermistor temperature is too low
65 Heat sink thermistor has disconnected or has shorted out
67 Outdoor brushless direct current (BLDC) fan motor lock error

Common LG Air Conditioner Problems

ProblemProbable CauseSolution

Air Conditioner Fan Won’t Run

Faulty fan blades or fan motor.Replace the faulty components as necessary.
Portable Air Conditioner has Low Cooling PerformanceWeak unit cooling capacity for the size of the room.Increase the number of units in the room.
Air Conditioner is Dripping WaterPoor installation of a window aircon unit.Re-install the unit to tilt outward.
Air Conditioner Unit Won’t Power OnTripped breaker; Failed compressor or capacitor.Contact a technician to diagnose and fix the issue.

My LG Air Conditioner Fan Isn’t Running

It’s time to replace the fan motor if the air conditioner is operating but neither the fan nor the fan motor are. It is crucial to get the AC serviced right away by a repair agency because the motor should have been changed much earlier than it ceased working.

Although LG air conditioners are quite robust, after prolonged usage, the fan and fan motor may still have issues. The fan of an air conditioner will wear down far more quickly if you leave it running constantly. Frequent air conditioner maintenance on should identify the worn motor and repair it before it totally breaks down.

My LG Portable Air Conditioner Cooling Performance is Low

Convenience is the design of portable air conditioners. They are not as cool, though, as tiny split air conditioners or window models. The size of your portable air conditioner is the issue if it is blowing cold air but is not cooling the space enough.

Move your air conditioner to a smaller place where it can operate efficiently, or think about adding another portable air conditioner to the room. This will enable you to maintain a pleasant temperature in the space and maximize the cooling power of your LG air conditioners.

My LG Window Air Conditioner is Dripping Water

Poor installation is frequently the cause of dripping water from a window air conditioner. When an air conditioner is installed improperly, it tilts inward rather than outward, and the water collection tank tends to leak within rather than outdoors.

Put your air conditioner back in place. If you choose a qualified air conditioning professional to handle the installation, you can be sure that the unit will be put correctly and won’t leak water all over your flooring. You won’t have to deal with the inconvenience of constantly emptying the condensation to enjoy that cozy, refreshing feeling.

How Do I Reset My LG Air Conditioner

Turn off the air conditioner and disconnect the power cable to reset your LG air conditioner. After unplugging the device for a minimum of 15 seconds, replace the plug. After you reset your device by pressing the power button, your LG air conditioner ought to start up and function normally once more.